As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFW - FLOORBEAM AT STA 347 HAS CORROSION REMOVAL ON UPPER SURFACE. BLENDED OUT CORROSION AND REFINISHED SURFACE PER SRM. FILLED BLENDED AREA WITH BM55-95. THE BLEND REPAIR IS SATISFACTORY FOR CONTINUED SERVICE WITH NOTED. TST: 49,449 HOURS. CYCLES: 5,146. (X)