What was found
DURING C-CHECK, FOUND FLOORBEAM STRUT FITTING CRACKED AT STATION 794 STRINGER23 RIGHT. REPLACED FITTING IAW DC9 SRM 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, FOUND FLOORBEAM STRUT FITTING CRACKED AT STATION 794 STRINGER23 RIGHT. REPLACED FITTING IAW DC9 SRM 51-30-5.