What was found
FLOOR SUPPORT STRUT FITTING CRACKED AT STATION 870R. REPLACED FLOOR SUPPORT STRUT IAW DC9 SRM 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT STRUT FITTING CRACKED AT STATION 870R. REPLACED FLOOR SUPPORT STRUT IAW DC9 SRM 51-30-5.