What was found
HEAVY CORROSION ON FRAME SPLICE ANGLE ON AFT SIDE OF FRAME AT STATION 943, ABOVE LONGERON 29 LEFT. REPLACED SPLICE ANGLE IAW DC-9 SRM 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HEAVY CORROSION ON FRAME SPLICE ANGLE ON AFT SIDE OF FRAME AT STATION 943, ABOVE LONGERON 29 LEFT. REPLACED SPLICE ANGLE IAW DC-9 SRM 51-30-5.