What was found
STEEL BEAM ABOVE THE RIGHT CLEARVIEW WAS RUSTED ON THE AFT END, BOTH INSIDE AND OUTSIDE OF BEAM. REPLACED BEAM IAW DC-9 SRM 51-30-1 AND 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STEEL BEAM ABOVE THE RIGHT CLEARVIEW WAS RUSTED ON THE AFT END, BOTH INSIDE AND OUTSIDE OF BEAM. REPLACED BEAM IAW DC-9 SRM 51-30-1 AND 51-30-5.