What was found
CORROSION FOUND ON NOSE LANDING GEAR WELL HORIZONTAL PRESSURE PANEL, BETWEEN FS 12 TO FS 27. ALSO FOUND CORROSION ON FLOORBEAM LOWER FLANGE AT FS 12, BUTT LINE '0'. REPAIRED AREA IAW REA 853-41975MR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON NOSE LANDING GEAR WELL HORIZONTAL PRESSURE PANEL, BETWEEN FS 12 TO FS 27. ALSO FOUND CORROSION ON FLOORBEAM LOWER FLANGE AT FS 12, BUTT LINE '0'. REPAIRED AREA IAW REA 853-41975MR.