SDR ABXA020368

Service difficulty report · Sensor · Doug DC932

Difficulty date
December 17, 2002
Submitted
December 26, 2002
Operation
Air carrier
Aircraft
N900AX
Make and model
Doug DC932
Aircraft serial
47380
Aircraft time
56,276 hours, 60,584 cycles
Part
Sensor
Part number
60714811
Part serial
101C2496
Condition
Out Of Tolerance
Location
Cabin Temp
Part time
16,128 hours, 13,529 cycles
Stage of operation
CR
How discovered
C
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

COCKPIT TEMP VALVE IN AUTO WENT TO 80 PERCENT FULL HOT. LT DUCT TEMP PEGGED OUT HOT. SLIGHT SMOKE IN COCKPIT. MANUALLY DROVE VALVE FULL COLD. AC SMOKE CHECKLIST RUN. LT BLEED VALVE OFF FOR REST OF FLT. FOUND AUTO TEMP CONTROL TO COCKPIT TEMP SENSOR OUT OF TOLERENCE. ADJUSTED. MANUAL TEMP OPS CHECKED GOOD IAW DC-9 MM 21-60-0. LINES RECONNECTED AND PLACARDS REMOVED.