As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSPECTION, ON LEFT STRUT FORWARD UPPER SPAR FITTING, FOUND FOUR BOLT HOLES SHOULD BE .4375 INCH ARE ALREADY OVERSIZED TO 0.515 INCH AND BACB 30 MT8X ARE INSTALLED. SB GIVES A MAXIMUM OVERSIZE OF 4692 INCH FOR THOSE HOLES. REWORKED AREA IAW REA B654-46255MR.