What was found
INTERMITTENT ODOR OF BURNING INSULATION UNDER THE GLARESHIELD ON FIRST OFFICER'S SIDE. FOUND BROKEN WIRE ON FIRST OFFICERS CLEARVIEW WINDOW ANTI-FOG WIRING. SUSPECT WIRE MAY HAVE BEEN ARCING CAUSING THE SMELL. REPAIRED BROKEN WIRE. FIRST OFFICER'S CLEARVIEW WINDOW ANTI-FOG OPERATIONAL CHECK GOOD.