What was found
MAIN ENTRY DOOR AFT UPPER DOOR STOP A3, HAD CRACK FROM STOP HOLE TOWARDS DOOR OPENING APPROXIMATELY .1875 INCH LONG. REPAIRED AREA IAW DC-9 SRM AND EA 53100131-001.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN ENTRY DOOR AFT UPPER DOOR STOP A3, HAD CRACK FROM STOP HOLE TOWARDS DOOR OPENING APPROXIMATELY .1875 INCH LONG. REPAIRED AREA IAW DC-9 SRM AND EA 53100131-001.