What was found
FOUND MAIN CABIN, STA 680, RIGHT BUTT LINE 26, LOWER SIDE OF FLOORBEAM CORRODED. REMOVED CORROSION IAW DC8 SRM 51-1-8, ORIGINAL MATERIAL THICKNESS 0.178", REMAINING THICKNESS 0.107" AND OUT OF LIMITS IAW DC8 SRM 53-2-0. VERIFIED REPAIR AINGLE AS AND10134-1407 PO NR 1122486. FABRICATED, LOCATED, AND DRILLED REPAIR PARTS IAW ABX DWG K04881. PRECOATED ALL BARE METAL IAW LWR NR 200302015, AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED REPAIR PARTS IAW DC8 SRM 51-1-20D AND ABX DWG K04881.