What was found
FOUND SHEAR TIE CRACKED AT STA 440, LONGERON 31 RIGHT (REF. NRC HY-275). REMOVED AREA STRUCTURE FOR ACCESS, REMOVED DAMAGED AREA OF FORMER SECTION/SHEAR TIE, LONGERON 30 RIGHT AND LONGERON 31 RIGHT, STA 440. FABRICATED REPAIR PARTS: 1 FORMER SECTION FROM 0.071" 2024-T3 AND 1 SPLICE DOUBLER FROM 0.071" 2024-T3. BOTH PO NR 1122792. FIT, TREATED, AND PRIMED PARTS. INSTALLED REPAIR PARTS. REINSTALLED STRUCTURE REMOVED FOR ACCESS REF DC8 SRM 53-2-0, FIG 2B.