What was found
HYDRAULIC QUANTITY DECREASED TO .46 QTY STABLE WITH EDP DEPRESSURIZED ACMP OFF. OPENED COWLINGS, SERVICED RIGHT HYDRAULIC SYSTEM IAW B767 MM. RIGHT ENGINE FOUND FLUID LEAK AT STRUT DISCONNECTOR, REPLACED O-RING. NO LEAKS NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HYDRAULIC QUANTITY DECREASED TO .46 QTY STABLE WITH EDP DEPRESSURIZED ACMP OFF. OPENED COWLINGS, SERVICED RIGHT HYDRAULIC SYSTEM IAW B767 MM. RIGHT ENGINE FOUND FLUID LEAK AT STRUT DISCONNECTOR, REPLACED O-RING. NO LEAKS NOTED.