What was found
1.125" LFEC CRACK INDICATION BETWEEN FASTENERS AT LOWER FORWARD CORNER. FASTENERS ARE AT EDGE OF CUTOUT AND COMMON TO DOOR SEAL DEPRESSOR. REPAIRED AFT LOWER CARGO LOWER FORWARD CORNER IAW DC9 SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
1.125" LFEC CRACK INDICATION BETWEEN FASTENERS AT LOWER FORWARD CORNER. FASTENERS ARE AT EDGE OF CUTOUT AND COMMON TO DOOR SEAL DEPRESSOR. REPAIRED AFT LOWER CARGO LOWER FORWARD CORNER IAW DC9 SRM.