What was found
AFT PRESSURE BULKHEAD CUTOUT UPPER RIGHT CORNER HAD APPROXIMATELY 1.20 INCH LONG CRACK IN DOUBLER WITH NO PREVIOUS REPAIR CONFIG INSTALLED. NOTE: UPPER LEFT CORNER PREVIOUS J060088-1 CONFIG REPAIRED DOOR CORNERS IAW DC9 SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PRESSURE BULKHEAD CUTOUT UPPER RIGHT CORNER HAD APPROXIMATELY 1.20 INCH LONG CRACK IN DOUBLER WITH NO PREVIOUS REPAIR CONFIG INSTALLED. NOTE: UPPER LEFT CORNER PREVIOUS J060088-1 CONFIG REPAIRED DOOR CORNERS IAW DC9 SRM.