As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ENTRY DOORS LIGHT ILLUMINATED WITHOUT ASSOCIATED DOOR EICAS MSG INSPECTED ENTRY DOOR PROX SENSOR S194 AND S195 NO DEFECTS FOUND. CLEANED SENSORS. BIT CHECK AT PSEU SHOWS NO FAULTS. FOLLOWED FIM 52- 71-00-1 TARGET TEST. NO DEFECTS FOUND.