What was found
FLAP MID SPAR WEB UPPER CORD STR 7 IS CORRODED AT LBL 38 JUST I/B OF RIB 2 VERTICAL FLANGE. REMOVED CORROSION AS REQUIRED IAW B767 SRM 55-10-03 AND REA B655-59827-MR, ACFT WAS GROUNDED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLAP MID SPAR WEB UPPER CORD STR 7 IS CORRODED AT LBL 38 JUST I/B OF RIB 2 VERTICAL FLANGE. REMOVED CORROSION AS REQUIRED IAW B767 SRM 55-10-03 AND REA B655-59827-MR, ACFT WAS GROUNDED.