What was found
HORIZONTAL CENTER SECTION LOWER RBL 41.5 STR 5 BETWEEN RIBS 2 & 3 HAS HEAVY CORROSION JUST OUTBOARD RIB 2R. CORRODED AREA FOUND TO BE OUT OF LIMITS, REPAIRED AREA IAW REA B655-60481-MR, ACFT WAS GROUNDED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HORIZONTAL CENTER SECTION LOWER RBL 41.5 STR 5 BETWEEN RIBS 2 & 3 HAS HEAVY CORROSION JUST OUTBOARD RIB 2R. CORRODED AREA FOUND TO BE OUT OF LIMITS, REPAIRED AREA IAW REA B655-60481-MR, ACFT WAS GROUNDED.