What was found
FWD LOWER CARGO ANGLE AT FUSELAGE BS 740 S32L TO 32R IS CORRODED ON BOTH UPPER & LOWER SIDES & HAS RUSTY NUTPLATES. R & R ANGLE AND INSTALLED NUT PLATES ON ANGLE IAW SRM 51-40-02. ACFT WAS GROUNDED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD LOWER CARGO ANGLE AT FUSELAGE BS 740 S32L TO 32R IS CORRODED ON BOTH UPPER & LOWER SIDES & HAS RUSTY NUTPLATES. R & R ANGLE AND INSTALLED NUT PLATES ON ANGLE IAW SRM 51-40-02. ACFT WAS GROUNDED.