What was found
BS 632, RBL 24, CORROSION UNDER NUTPLATES ON FLOORBEAM UPPER TEE. FABRICATED FLOORBEAM UPPER TEE IAW DWG 143T1209, PO: 0037850.ACFT WAS GROUNDED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 632, RBL 24, CORROSION UNDER NUTPLATES ON FLOORBEAM UPPER TEE. FABRICATED FLOORBEAM UPPER TEE IAW DWG 143T1209, PO: 0037850.ACFT WAS GROUNDED.