As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SUPPORT BRACKET FOR OVERWING PANEL IS CHAFED ON TOP INBD SIDE BY INBD FWD SIDE OF LT INBD AILERON. R & R INBD UPPER PANEL SUPPORT BEAM FWD SIDE OF LT INBD AILERON IAW SRM 51-40-02. SDR INFO PN 113T1944-49, SN NA, PART NAME BEAM, LOCATION WS 437 TO WS 447, CHAFE DAMAGE BEYOND LIMITS. ACFT WAS GROUNDED.