What was found
STRINGER CRACKED AT STATION 676 STRINGER 6L. REMOVED DAMAGED STRINGER, FABRICATED & INSTALLED STRINGER & REPAIR SPLICE IAW REA653-60886, SRM 51-40-02 & 53-00-03. SDR INFO CRACKED .750, PN 143T3001-6, PART NAME STRINGER, SN NSN, FUSELAGE STATION LOCATION 676 TO 710, STRINGER LOCATION 6L. ACFT WAS GROUNDED.