What was found
LEFT HORIZONTAL STAB TIP LOWER FLANGE IS CORRODED, FORWARD END. BLENDED CORROSION IAW AMM 51-00-03. BLENDED AREA OUT OF LIMITS IAW SRM 55-10-09. REPLACED LWR CHORD IAW DWG 182T5800, PN 182T5800-41. SDR INFO CORRODED LEVEL 2, PN 182T5800-41, PART NAME CHORD, SN NSN, STRINGER & WS LOC HSBL 357.442 LE TO HSBL 357.442 LE ACFT WAS GNDED.