What was found
STATION 1329 ABOVE STRINGER 33R, FLOORBEAM UPPER FLANGE CORRODED IN THE CORNER. REMOVED CORRODED INTERCOSTAL AT BS 1329 ABOVE STRINGER 33 RT, LOCATED & DRILLED FABRICATED IAW REA B653-60989 & INSTALLED INTERCOSTAL IAW B653- 60989 & SRM B767 51-40-02-0G, SB-106 5/1/14. SDR INFO CORRODED, PN 146T5000-38, PART NAME SUPPORT, SN NSN, FS & BS LOCATION 1329 - 1351, STRINGER & WS LOCATION STRINGER 35R. ACFT WAS GNDED.