What was found
REMOVED GENERAL DAMAGE ON KEEL BEAM AT STATION 993R, BL9. FOUND TO BE IN LIMITS IAW SRM 53-50-12 SB-47 5-28-14, NOMINAL THICKNESS .369, REMOVED .043, REMAINING THICKNESS .326. CORRODED L2, PN 14ST8610-1, PART NAME KEEL BEAM, NR 3 SLAT OTBD AUX TRACK ATTACH FITTING SHIM ON OTBD LOWER, SN NSN, BS LOCATION FROM 992 TO 993, STRINGER & WS LOCATION FROM RBL 9. ACFT WAS GNDED.