What was found
OUTBOARD AIR LOAD STRUT CORRODED AT NR 8 SLAT INBD AUX TRACK AREA. CLEANED AREA IAW SRM 51-10-00. REMOVED .005 ORIGINAL MATERIAL, AREA IS WITHIN IMITS IAW SRM 57-41-09. TREATED & PRIMED AREA IAW SRM 51-20- 01. PAINTED AREA IAW AMM 51-21-10. CORRODED L2, PN 114T2201, SN N/A, PART NAME AIR LOAD STRUT, STR & WS LOC ON ACFT LES 440. ACFT WAS GNDED.