What was found
LOWER LE PANEL SPAR CRACKED & CORRODED AT NR 1 SLAT INBD AUX TRACK AREA. REMOVED DAMAGED & CORRODED SECTION OF LOWER LE SPLICE PLATE & INSTALLED NEW SECTION OF SPLICE PLATE IAW REA B657-61054. ACFT WAS GROUNDED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LOWER LE PANEL SPAR CRACKED & CORRODED AT NR 1 SLAT INBD AUX TRACK AREA. REMOVED DAMAGED & CORRODED SECTION OF LOWER LE SPLICE PLATE & INSTALLED NEW SECTION OF SPLICE PLATE IAW REA B657-61054. ACFT WAS GROUNDED.