What was found
RIGHT 1809 CHORD CRACKED AREA 2 FWD LOWER LE. FWD LOWER FASTENER OF AREA 1 NEEDS REMOVED TO VERIFY DEFECT INDICATION IAW STEP 11 OF TASK CARD NEA53800003-001. REPAIRED CHORD IAW SB 767-53A0078. CRACKED, LENGTH .5, PN 015T1059-4, PART NAME CHORD, SN NSN, FS & BS LOCATION FROM 1809 - 1809 STRINGER & WS LOCATION FROM STRINGER 12R TO 14R. ACFT WAS GNDED.