What was found
CRACKED SUPPORT ANGLE AT AFT END OF FORE TO AFT LOWER BEAM AT REAR SPAR APPROX RBL 42. FABRICATED NEW SUPPORT ANGLE FROM 2075-0-090 PO 0055105. HEAT TREATED TO 2075-T6 IAW DWG 111T1000. CRACKED 4.7 INCHES, PN 111T1000, PART NAME ANGLE, SN NSN, FS & BS LOCATION 970 TO 975, STRINGER & WS LOCATION RBL 42 TO RBL 42. ACFT WAS GNDED.