What was found
FASTENER HOLE ON NR 1 SUPPORT 1, 2, 3 BEAM RT SIDE FWD OF NR 2 JOINT UPPER HOLE HAS DAMAGE IN HOLE. REAMED HOLE & INSTALLED OVERSIZED FASTENER IAW REA-C027-61321-MR. HOLE DAMAGE, PART NR 113T1313-7, PART NAME FLAP SUPPORT, 1 - 3 BEAM, EXACT LOCATION 800, SN ABXT803. ACFT WAS GNDED.