What was found
STRUCTURAL WEB IS CRACKED AT THE FWD MOST NOSE COWL ANTI-ICE DUCT SUPPORT ROD BRACKET. REMOVED DAMAGED WEB, FABRICATED & INSTALLED NEW WEB IAW SRM 51-40-02 & DWG 311T1510. CRACKED 3.2 INCHES, PN 311T1510-59, SN N/A, PART NAME WEB, FS & BS LOCATION ON ACFT NAC WL 150, STRINGER WS LOCATION ON ACFT WS 166 TO WS 169.8. ACFT WAS GNDED.