What was found
VERTICAL STABILIZER TO SKIN ANGLE LT OTBD END CRACKED, ACCESS THROUGH PANEL 324AL. REMOVED ANGLE, FABRICATED NEW ANGLE IAW DWG 173T1302 FROM 2024-T3 .040. PERFORMED HFEC INSPECTION. INSTALLED NEW ANGLE IAW SRM 5140-02. SDR INFO, CRACKED 1.900", PN 173T1302-1, SN N/A, PART NAME ANGLE, FS LOCATION ON ACFT FS 1725.5 TO 1746.5, STRINGER & WS LOCATION ON ACFT, STRINGER 2L TO 2R. ACFT WAS GNDED.