What was found
LEFT HORIZONTAL STABILIZER UPPER REAR BEAM HAS AREAS OF CORROSION FROM ELEVATOR STATION 49 - 302. OUT OF LIMITS AREA ELEVATOR STATION 146 - 150.5. REPAIRED IAW REA B655-61427. THREE BLEND LOCATIONS FOUND TO BE WITHIN ACCEPTABLE LIMITS WHEN COMBINING SRM 55-10-13 FIG 101 & DWG TOLERANCES IAW ENGINEERING. REMAINING CORROSION ON BEAM BLENDED WITHIN LIMITS IAW SRM 55-10-13 FIG 101. SDR INFO, PN 183T1701, PART NAME AFT UPPER BEAM, SN NSN, CORRODED LEVEL 2, EXACT FS & BS LOCATION ON ACFT ELEVATOR STATION 49.5 TO 302. ACFT WAS GNDED.