What was found
NUMBER 1 ENG AFT FAIRNG, MOST FWD FRAME STATION ALONG BOTTOM OF FAIRING ASSEMBLY IS CRACKED IN SEVERAL LOCATIONS , AS VIEWED FROM INBD SIDE OF FAIRING LOOKING FWD. R & R FRAME CHANNEL & B STIFFENER ANGLE AT NR 1 ENG AFT FAIRING MOST FWD FRAME IAW SRM 51-40-02 PARAGRAPH 7. CRACKED 2 INCHES, PN 313T2380-279, PART NAME OTBD STIFFENER & CHANNEL, SN FS & BS LOCATION EXACT NAC 308.37. ACFT WAS GNDED.