What was found
UPON CURSORY INSPECTION, FOUND CORROSION WITHIN AREA UNDER THIRD INBD HEAT SHIELD PANEL AT LOWER AFT PYLON AREA, APPROX NAC STATION 400. R & R CORRODED T FITTING IAW BCSF SRM 51-40-02 & DWG 313T1355. SDR INFO, CORRODED LEVEL 2, PN 313T1355-128, PART NAME T FITTING, SN NSN, FS & BS LOCATION FROM NAC STATION 398 - 400. ACFT WAS GNDED.