What was found
NUMBER 6 SLAT LOWER TE ATTACH ANGLE, LOCATED OUTBOARD OF OUTBOARD AUX TRACK IS CRACKED. R & R ATTACH ANGLE, INSTALLED FASTENERS IAW SRM 51-40-02 PARAGRAPH 7D & 9B. SDR INFORMATION CRACKED LENGTH .250, PN 114T3166-71, SN N/A, PART NAME ANGLE, EXACT FS & BS LOCATION ON ACFT FROM ISS 327, EXACT STRINGER & WS LOCATION ON ACFT NR 6 SLAT. ACFT WAS GNDED.