What was found
LOWER FRAME CORRODED, AT STATION 742L, BETWEEN STRINGER 34L & 36L, IN THREE PLACES. BLENDED CORROSION, SHEAR TIE OUT OF LIMITS, TO BE REPAIRED ON NON-ROUTINE 0822. BLENDED WEB STATION 742L, STRINGER 34 - 35L. ORIGINAL MT .032, REMOVED .003, REMAIN .029 WITHIN LIMITS IAW SRM 53-00-07, NO CORROSION FOUND. CORRODED LEVEL 2, PN IAW DWG 143T1214, PART NAME CHORD, WEB SHEAR TIE, EXACT FS & BS LOCATION ON ACFT, FROM STATION 742L TO BL 21 - 26L. ACFT WAS GNDED.