What was found
STATION 676, STRINGER 4L SPLICE HAS 3/4" CRACK ON VERTICAL LEG FWD SIDE OF FRAME. CONTACT ENGINEERING FOR REPAIR. COMPLETE M 289, REF NEA53100137-201. R & R SPLICE IAW B767 SRM 51-40-02 REA B653-61924MR. CRACKED LENGTH .650, PN 368-53-00-95387, SN N/A, PART NAME SPLICE FITTING, EXACT FS & BS LOCATION ON ACFT, FROM STATION 676, EXACT STRINGER & WS LOCATION ON ACFT FROM STRINGER 14L. ACFT WAS GNDED.