What was found
BULK CARGO DOOR CUT OUT LOWER WEB, LOWER SURFACE CORRODED. REMOVED FLOOR PANEL TO STATION 1417 - 1540, BL 0 - LBL 42. REMOVED CORROSION FROM WEB IAW SRM. CORROSION REMOVAL BEYOND LIMITS IAW SRM 53-00, THICKNESS 0.100 WITH 0.050 REMAINING, 0.050 MATERIAL REMOVAL TOOL. REMOVED WEB IAW SRM 51-40-02. COUNTERSANK & INSTALLED NEW FLOOR PLATE WEB, STATION 1417 - 140 146T8211 REV B. APPLIED TOP COAT IAW SRU1 51-2 FLOOR PANEL IAW AMM 53-01-05. REMOVED DOT, PART PLATE, PN 146T8211-7. ACFT WAS GNDED.