What was found
HEAVILY CORRODED AREA ON SKIN & TEAR STRAP AT STATION 1065, FWD SIDE JUST BELOW STRINGER 8R. REMOVED STRINGER 8R FROM STATION 1065 - 1043 TO ACCESS CORROSION. BLENDED CORROSION, AREA WAS FOUND TO BE ACCEPTABLE FOR CONTINUED SERVICE WHEN COMBINING ON 145T0400. REPAIRED STRINGER 8R IAW SRM 53-00-03 FIG 201. CORRODED LEVEL 2, PN 145T3001-5, PART NAME STRINGER, SN NSN, FS & BS LOCATION AT STATION 1043. ACFT WAS GNDED.