What was found
LEFT FAILSAFE LOWER HOLE COMMON TO T FITTING HAS CRACK INDICATION, VERIFIED BY HFEC ROTARY HOLE SCAN. TRIMMED OUT CRACK ON FAILSAFE STRAP COMMON TO T FITTING IAW DOCUMENT 47008ORD03, THAT IS ATTACHED TO JC EA 53500013-003 FOR WORK STEPS TAKEN. CRACKED LENGTH 125", PN 145T2524-21, PART NAME FAILSAFE STRAP, SN NSN, EXACT FS & BS LOCATION ON ACFT AT STATION 955, EXACT STRINGER & WS LOCATION ON ACFT AT WL 178. ACFT WAS GNDED.