What was found
LOWER FASTENER HOLE IN RT FAILSAFE COMMON TO T FITTING IS CRACKED, VERIFIED BY HFEC HOLE SCAN. TRIMMED OUT CRACK ON FAILSAFE STRAP COMMON TO T FITTING IAW DOCUMENT 47008ORD04, THAT IS ATTACHED TO JC EA 53500014-003 FOR WORK STEPS TAKEN. CRACKED LENGTH .125", PN 145T2524-22, PART NAME FAILSAFE STRAP, SN NSN, EXACT FS & BS LOCATION ON ACFT AT STATION 955, EXACT STRINGER & WS LOCATION ON ACFT AT WL 178. ACFT WAS GNDED.