What was found
LEFT STA 859.5, LBL89 LOWER LT SIDE FRAME INNER CHORD CRACKED IN RADIUS ON LOWER END, VERIFIED BY EDDY CURRENT. REMOVED FASTENERS, COMPLIED WITH EA 53000047-101. REMOVED FASTENERS WERE REPLACED WITH NEW IAW EA53000047-101. CRACKED LENGTH .250", PN: 145T1052-1, INNER CHORD, FS/BS LOCATION: 859.5, STR WING STA: LBL89. ACFT WAS GROUNDED.