What was found
RIGHT PRESSURE DECK WEB IS CORRODED. NEW WEB WAS FABRICATED FROM 2024-T3 .125 CLAD ALUMINUM PO 0085417, 2 EA EDGES WERE MACHINED IAW SAMPLE, AND WEB WAS TREATED PRIMED AND PAINTED IAW DWG 145T8752 AND AMM 51-21-02. TO BE INSTALLED ON DOC 47008ORD04. CORRODED LEVEL 2, PN: 145T8752-236, PRESSURE CHECK WEB, FS/BS LOCATION: FROM 955 TO 971. ACFT WAS GROUNDED.