What was found
RT ENG EEC INOP LIGHT ILLUMINATED WITH ASSOCIATED RT ENG EEC EICAS MESSAGE DISPLAYED DURING T.O. ROLL. ABORTED TAKE OFF AND AIRCRAFT RETURNED TO BLOCK. AIRCRAFT GROUNDED BY MAINTENANCE. MAINTENANCE TROUBLESHOT RT EEC SYSTEM. REMOVED OLD, THEN INSTALLED NEW R/H ELECTRICAL T.12 SENSOR PER AMM 73-21-06. TEST OF R/H SENSOR AND EEC OK PER AMM 73-21-07. CONDUCTED TEST 3, 4, 11 PER AMM 71-00-00/501, ALL TESTS PASSED. A/C REMAINS ETOPS 180, AIRCRAFT RETURNED TO SERVICE.