What was found
LEFT AOA EICAS ILLUMINATED AFTER ENGINE START. AIRCRAFT BACK TO BLOCK AND GROUNDED BY MAINTENANCE. MAINTENANCE FOUND LH AOA CIRCUIT BREAKER POPPED RESET DUE TO PITOT STATIC WORK OVER WEEKEND PERFORMED P-61 MISC TEST FOR 30 SEC THEN 25 SEC LH AOA PROBE HEAT TESTS OK REF AMM 30-32-00. AIRCRAFT RETURNED TO SERVICE.