What was found
DURING C21 MAINTENANCE CHECK AT HAECO AMERICAS, DENT AND CRACK DAMAGE WAS FOUND ON THE FUSELAGE SKIN P/N 148T3251-4. THE DAMAGE IS LOCATED AT STA 1710.5 BELOW THE S-36L SKIN LAP JOINT WITHIN A SKIN CHEM MILLED POCKET WITH A THICKNESS OF 0.056-INCH. THERE ARE NO APPLICABLE REPAIRS IN THE SRM FOR THIS DAMAGE LOCATION. THE REPAIR ACCOMPLISHED IS ACCEPTABLE AND HAS STAGE 1 APPROVAL FOR STATIC STRENGTH PER FAA FORM 8110-3 SIGNED BY ROBERT MANASHI, DER T 876272412, DATED 08-JUN-2023. REPAIRED PER ABX-REA-5385-65041-00.