What was found
DURING TAXI STARTING LH ENGINE THERE WAS NO ROTATION ON LH ENGINE , A/C RETURNED TO THE GATE (BTB) AND MTX GROUNDED A/C . MTX DEFERRED LH ENGINE START VALVE IAW MEL ABX-80-00-2-1 . AND RETURNED A/C TO SERVICE .AC REMAINS NO ETOPS
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING TAXI STARTING LH ENGINE THERE WAS NO ROTATION ON LH ENGINE , A/C RETURNED TO THE GATE (BTB) AND MTX GROUNDED A/C . MTX DEFERRED LH ENGINE START VALVE IAW MEL ABX-80-00-2-1 . AND RETURNED A/C TO SERVICE .AC REMAINS NO ETOPS