What was found
DURIING LUBE, MAINTENANCE IN LAX (LOS ANGELES, CA), FOUND THE RH MLG RETRACT ACTUATOR ROD END BEARING BROKEN. ABX AIR MAINTENACE CONTROL CONTACTED AMES EMGINEERING FOR ANALYSIS AND DISPOSITION FOR A GEAR DOWN FERRY FLIGHT TO CVG, PER ABX-REA-3200-65748-02. AFTER FERRY FLIGHT A/C WAS GROUNDED. CURRENTLY IN WORK FOUND RT MLG FWD LUG WHERE RETRACT ACTUATOR ATTACHES WAS DAMAGED. AN AMENDED SDR WILL BE SENT WHEN WORK IS COMPLETED.