What was found
DURING C6 CHECK AT HACECO INSPECTION FOUND E&E DOOR CUTOUT FWD FRAME WEB STA303 HAS PUNCTURE REMOVED ANGLE SUPPORT RAIL IAW B767 SRM 51-40-02, REMOVED DAMAGE IAW B767 53-00-07 REPAIR 3. MATL ID FOR FILLER .032 7075 PO1060506.1 AND DOUBLER 7075 T6 .040 PO 983717.3 IAW B767 SRM 53-10-07. FABRICATED FILLER AND DOUBLER IAW B767 SRM 53-00-07 REPAIR 3. ALODINED AND PRIMED IAW B767 SRM 51-20-01 DOUBLER AND FILLER. INSTALLED DOUBLER FILLER AND ANGLE SUPPORT IAW B767 51-40-02. INSTALLED RAIL IAW B767 SRM 51-40-02.FORM M-287 AND FAA FORM 337 ATTACHED.